• C-B60 Butterfly coil

    0.00$

    PRODUCT #MV9016E0482

    Suitable coil for focused stimulations. Equipped with power control and trigger button to support clinical operation.

    • Diameter: 2 x 75mm
    • Pulses before warmup: 350
    • Built-in powercontrol
    • Trigger button
    • Compatible with all stimulators

    FEATURES

    • Weight of transducer head 700g
    • Cable length 1.7m
    • Dimensions of transducer head 165 x 85 x 19 mm

    Coil Winding Data:

    • Inner diameter 35mm
    • Outer diameter 75mm
    • Winding height 11mm
    • Number of windings 2 x (2 x 5)

     

    Magnetic and Electrical Properties:

    • Max initial dB/dt 35 kT/s near the coil surface.
    • Active pulse width 280µs (Biphasic)

     

    Performance:

    • Number of stimulations, before warm-up at ambient temperature 20°C: Mean output 75% of maximum at 1pps.
    • 350 pulses

  • Coil Cooling Unit for Cool Coils

    0.00$

    PRODUCT #MV9016B0151

    Used as external cooling system for Cool coils.

    • Equipped with special liquid cooling media.

    FEATURES

    • Weight of unit 10kg
    • Height x width x depth 20 x 30 x 30 cm
    • Capacity of cooling media 1,8 liter
    • Mains power cable length 3m
    • Available Main Voltage 100-240V, 50-60Hz
    • Power consumption Maximum 40VA

  • Cool D-B80 Butterfly Coil

    0.00$

    PRODUCT #MV9016E0582

    Electrical and magnetic properties like the D-B80. Suitable for deep stimulation. Designed for demanding stimulation protocols requiring a very high number of stimuli. Equipped with trigger button to support clinical operation. Built in EPV timer and counter (5 years or 18 million EPV, which ever comes first).

    • Diameter: 2 x 95mm
    • Angulated 120º
    • Pulses before warmup: >20.000
    • Trigger button
    • Cooled dynamically with external coil cooler unit
    • Compatible with R30 & X100

    FEATURES

    • Weight of transducer head 1.8 kg
    • Cable length 1.3 m

    Dimensions of transducer head:

    • 2 x ø110mm
    • Thickness 30mm
    • Angle 120°C

     

    Coil Winding Data

    • Inner diameter 67 mm
    • Outer diameter
    • Winding height 12 mm
    • Number of windings 2 x (3+4)

     

    Magnetic and Electrical Properties

    • Max initial dB/dt 31 kT/s near the coil surface.
    • Active pulse width 280µs (Biphasic)

     

    Performance

    • Number of stimulations, before warm-up at ambient temperature 20°C, output 75% of maximum at 2 pps.
      >20.000 pulses
    • Number of stimulations, before warm-up at ambient temperature 20°C, output 75%, protocol: 60 trains @ 50 pulses/train @ 10pps and Inter Train Interval 25 sec.
      >10.000 pulses

  • Cool-B65 Butterfly Coil

    0.00$

    PRODUCT #MV9016E0491

    Designed for demanding stimulation protocols requiring a very high number of stimuli. Optimized for high repetition rates and long pulse trains. Cooled from an external Cooler Unit. Equipped with trigger button to support clinical operation. Built in EPV timer and counter (5 years or 18 million EPV, whichever comes first).

    • Diameter: 2 x 75mm
    • Pulses before warmup: >20.000
    • Trigger button
    • Cooled dynamically with external coil cooler unit
    • Compatible with R30, R100 & X100

    FEATURES

    • Weight of transducer head 1,7kg
    • Cable length 1,3m
    • Dimensions of transducer head 174 x 94 x 41 mm

    Coil Winding Data:

    • Inner diameter 35mm
    • Outer diameter 75mm
    • Winding height 12mm
    • Number of windings 2x (2 x 5)

     

    Magnetic and Electrical Properties:

    • Max initial dB/dt 36 kT/s near the coil surface.
    • Active pulse width 280µs (Biphasic)

     

    Performance:

    • Number of stimulations, before warm-up at ambient temperature 20°C: Mean output 75% of maximum at 2pps. >20.000 pulses
    • Number of stimulations, before warm-up at ambient temperature 20°C with protocol: 60 trains @ 50 pulses/train @ 10pps @ Inter Train Interval: 25s @ Output=75%. >10.000 pulses

  • D-B80 Butterfly Coil

    0.00$

    PRODUCT #MV9016E0431

    Opened butterfly design for powerful stimulation. The coil is suitable for deep stimulation. The coil is slightly bend to closely follow curved shapes. Equipped with trigger button to support clinical operation.

    • Diameter: 2 x 95mm
    • Angulated 120º
    • Pulses before warmup: 500
    • Trigger button
    • Compatible with R30, R100 & X100
    • Usable with MagPro Compact w/ converter

    FEATURES

    • Weight of transducer head 900g
    • Cable length 1,7m
    • Angle 120°C

    Coil Winding Data:
    Inner diameter 67mm
    Outer diameter 95mm
    Winding height 12mm
    Number of windings 2 x (3+4)

     

    Magnetic and Electrical Properties:
    Max initial dB/dt 31 kT/s near the coil surface.
    Active pulse width 280µs (Biphasic)

     

    Performance:
    Number of stimulations, before warm-up at ambient temperature 20°C: Mean output 75% of maximum at 1 pps, 500 pulses

  • MCF-B65 Butterfly Coil

    0.00$

    PRODUCT #MV9016E0423

    The Coil is designed for demanding stimulation protocols, requiring a high number of stimuli without the need for external cooling. Equipped with trigger button to support clinical operation.

    • Diameter: 2 x 75mm
    • Pulses before warmup: 2000
    • Trigger button
    • Cooled with static fluid
    • Compatible with R30, R100 & X100

    FEATURES

    • Weight of transducer head 1,5kg
    • Cable length 2m
    • Dimensions of transducer head 174 x 94 x 53 mm

    Coil Winding Data:

    • Inner diameter 35mm
    • Outer diameter 75mm
    • Winding height 12mm
    • Number of windings 2x (2 x 5)

     

    Magnetic and Electrical Properties

    • Max initial dB/dt 32 kT/s near the coil surface.
    • Active pulse width 280µs (Biphasic)

     

    Performance:

    • Number of stimulations, before warm-up at ambient temperature 20°C: Mean output 75% of maximum at 1pps. 2000 pulses

  • MCF-B70 Butterfly Coil

    0.00$

    PRODUCT #MV9016E0582

    Electrical and magnetic properties similar to the MC-B70. Designed for demanding stimulation protocols requiring a high number of stimuli without the need for external cooling.

    Designed with a slightly bend surface for best possible skull contact. Large ergonomic handle and equipped with trigger button to support clinical operation.

    FEATURES

    • Weight of transducer head: 2.5 kg
    • Cable length: 1.3 m
    • Angle: 150°

    Dimensions of transducer head:

    • 180 x 116 x 46/64 mm

     

    Coil Winding Data:

    • Inner diameter 23 mm
    • Outer diameter 96 mm
    • Winding height 12 mm
    • Number of windings 2 x 11

     

    Magnetic and Electrical Properties:

    • Max initial dB/dt 28 kT/s near the coil surface.
    • Active pulse width 280µs (Biphasic)

     

    Performance:

    • Number of stimulations, before warm-up at ambient temperature 20°C: Mean output 75% of maximum at 1pps. 5500 pulses.

     

    Protocol:

    • 60 trains @ 50 pulses/train @ 10pps @ Inter Train Interval: 25s @ Output=75% @ total number of stimulations 3000.
    • One protocol can be performed without overheating the coil. Minimum cooling time between protocols: 2.5 hours at 20°C or 1 hour at 7°C